4.2 SPACE ALLOWANCE AND REACH RANGES.

4.2.1* WHEELCHAIR PASSAGE WIDTH.

The minimum clear width for single wheelchair passage shall be 32 in (815 mm) at a point and 36 in (915 mm) continuously (see Fig. 1 and 24(e)).

The minimum clear passage width for a single wheelchair shall be 36 inches (915 mm) minimum along an accessible route, but may be reduced to 32 inches (815 mm) minimum at a point for a maximum depth of 24 inches (610 mm), such as at a doorway.

Figure 1

Minimum Clear Width for Single Wheelchair

Diagram shows 32 inches (815 mm) clear width at doorway with a maximum doorway depth of 24 inches (610 mm).

Figure 24(e)

Maximum Doorway Depth

4.2.2 WIDTH FOR WHEELCHAIR PASSING.

The minimum width for two wheelchairs to pass is 60 in (1525 mm) (see Fig. 2).

Diagram shows 60 inches (1525 mm) minimum clear width for two wheelchairs.

Figure 2

Minimum Clear Width for Two Wheelchairs

4.2.3* WHEELCHAIR TURNING SPACE.

The space required for a wheelchair to make a 180-degree turn is a clear space of 60 in (1525 mm) diameter (see Fig. 3(a)) or a T-shaped space (see Fig. 3(b)).

Diagram shows a wheelchair turning space of 60 inches (1525 mm) minimum.

Figure 3(a)

60-in (1525 mm) Diameter Space

The T-shape space is 36 inches (915 mm) wide at the top and stem within a 60 inch by 60 inch (1525 mm by 1525 mm) square.

Figure 3(b)

T-Shaped Space for 180 Degree Turns

4.2.4.1 SIZE AND APPROACH.

The minimum clear floor or ground space required to accommodate a single, stationary wheelchair occupant is 30 in by 48 in (760 mm by 1220 mm) (see Fig. 4(a)). The minimum clear floor or ground space for wheelchairs may be positioned for forward or parallel approach to an object (see Fig. 4(b) and (c)). Clear floor or ground space for wheelchairs may be part of the knee space required under some objects.

Figure 4

Minimum Clear Floor Space for Wheelchairs

Diagram shows 30 inches (760 mm) by 48 inches (1220 mm) minimum clear floor space for a wheelchair.

Figure 4(a)

Clear Floor Space

Diagram shows 30 inches (760 mm) by 48 inches (1220 mm) minimum clear floor space for a wheelchair, for forward approach.

Figure 4(b)

Forward Approach

Diagram shows 30 inches (760 mm) by 48 inches (1220 mm) minimum clear floor space for a wheelchair, for parallel approach.

Figure 4(c)

Parallel Approach

4.2.4.2 RELATIONSHIP OF MANEUVERING CLEARANCE TO WHEELCHAIR SPACES.

One full unobstructed side of the clear floor or ground space for a wheelchair shall adjoin or overlap an accessible route or adjoin another wheelchair clear floor space. If a clear floor space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearances shall be provided as shown in Fig. 4(d) and (e).

Figure 4 (cont.)

Minimum Clear Floor Space for Wheelchairs

For a front approach, where the depth of the alcove is equal to or less than 24 inches (610 mm), the required clear floor space is 30 inches by 48 inches (760 mm by 1220 mm). For a side approach, where the depth of the alcove is equal to or less than 15 inches (380 mm), the required clear floor space is 30 inches by 48 inches (760 mm by 1220 mm).

Figure 4(d)

Clear Floor Space in Alcoves

For a front approach, if the depth of the alcove is greater than 24 inches (610 mm), then in addition to the 30 inch (760 mm) width, a maneuvering clearance of 6 inches (150 mm) in width is required. For a side approach, where the depth of the alcove is greater than 15 inches (380 mm), then in addition to the 48 inch (1220 mm) length, an additional maneuvering clearance of 12 inches in length (305 mm) is required.

Figure 4(e)

Additional Maneuvering Clearances for Alcoves

4.2.4.3 SURFACES FOR WHEELCHAIR SPACES.

Clear floor or ground spaces for wheelchairs shall comply with 4.5.

4.2.5 FORWARD REACH.

If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a)). The minimum low forward reach is 15 in (380 mm). If the high forward reach is over an obstruction, reach and clearances shall be as shown in Fig. 5(b).

Figure 5

Forward Reach

Plan diagram showing 30 inches (760 mm) by 48 inches (1220 mm) clear floor space for a wheelchair. Side elevation showing 15 inches (380 mm) minimum to 48 inches (1220 mm) forward reach limits.

Figure 5(a)

High Forward Reach Limit

The maximum level forward reach over an obstruction with knee space below is 25 inches (635 mm). When the obstruction is less than 20 inches (510 mm) deep, the maximum high forward reach is 48 inches (1220 mm). When the obstruction projects 20 to 25 inches (510 mm to 635 mm), the maximum high forward reach is 44 inches (1120 mm).

Figure 5(b)

Maximum Forward Reach over an Obstruction

4.2.6* SIDE REACH.

If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9 in (230 mm) above the floor (Fig. 6(a) and (b)). If the side reach is over an obstruction, the reach and clearances shall be as shown in Fig. 6(c).

Figure 6

Side Reach

The 30 by 48 inch clear floor space is located a maximum 10 inches (255 mm) from the wall.

Figure 6(a)

Clear Floor Space - Parallel Approach

The 30 by 48 inch wheelchair clear floor space is located a maximum 10 inches (255 mm) from the wall.

Figure 6(b)

High and Low - Side Reach Limits

If the depth of the obstruction is 24 inches (610 mm) and the maximum height of the obstruction is 34 inches (865 mm), the maximum high side reach over the obstruction is 46 inches (1170).

Figure 6(c)

Maximum Side Reach over Obstruction