Uniform Federal Accessibility Standards (UFAS)

4.22 TOILET ROOMS.

4.22.1 MINIMUM NUMBER.

Toilet facilities required to be accessible by 4.1 shall comply with 4.22. Accessible toilet rooms shall be on an accessible route.

4.22.2 DOORS.

All doors to accessible toilet rooms shall comply with 4.13. Doors shall not swing into the clear floor space required for any fixture.

4.22.3 CLEAR FLOOR SPACE.

The accessible fixtures and controls required in 4.22.4, 4.22.5, 4.22.6, and 4.22.7 shall be on an accessible route. An unobstructed turning space complying with 4.2.3 shall be provided within an accessible toilet room. The clear floor space at fixtures and controls, the accessible route, and the turning space may overlap.

EXCEPTION: In toilet rooms with only one water closet and one lavatory, a clear floor space of 30 in by 60 in (815 mm by 1525 mm) may be used in lieu of the unobstructed turning space.

4.22.4 WATER CLOSETS.

If toilet stalls are provided, then at least one shall comply with 4.17; its water closet shall comply with 4.16. If water closets are not in stalls, then at least one shall comply with 4.16.

4.22.5 URINALS.

If urinals are provided, then at least one shall comply with 4.18.

4.22.6 LAVATORIES AND MIRRORS.

If lavatories and mirrors are provided, then at least one of each shall comply with 4.19.

4.22.7 CONTROLS AND DISPENSERS.

If controls, dispensers, receptacles, or other equipment is provided, then at least one of each shall be on an accessible route and shall comply with 4.27.