Hello. Please sign in!

Uniform Federal Accessibility Standards (UFAS)

4.31 TELEPHONES.

4.31.1 GENERAL.

Public telephones required to be accessible by 4.1 shall comply with 4.31.

4.31.2 CLEAR FLOOR OR GROUND SPACE.

A clear floor or ground space at least 30 in by 48 in (760 mm by 1220 mm) that allows either a forward or parallel approach by a person using a wheelchair shall be provided at telephones (see Fig. 44). The clear floor or ground space shall comply with 4.2.4. Bases, enclosures, and fixed seats shall not impede approaches to telephones by people who use wheelchairs.

Figure 44

Mounting Heights and Clearances for Telephones

 If a parallel approach is provided at a telephone in an enclosure, the wing walls and shelf may extend beyond the face of the telephone a maximum of 10 inches (255 mm).

* Height to highest operable parts which are essential to basic operation of telephone

If a parallel approach is provided at a telephone in an enclosure, the wing walls and shelf may extend beyond the face of the telephone a maximum of 10 inches (255 mm).

Figure 44(a)

Side Reach Possible

If a front approach is provided at a telephone with an enclosure, the shelf can extend beyond the face of the telephone a maximum of 20 inches (510 mm). A wing wall may extend beyond the face of the telephone a maximum of 24 inches (610 mm). If the wing wall extends more than 24 inches (610 mm) beyond the face of the telephone, an additional 6 inches (150 mm) in width of clear floor space shall be provided.

* Height to highest operable parts which are essential to basic operation of telephone

If a front approach is provided at a telephone with an enclosure, the shelf can extend beyond the face of the telephone a maximum of 20 inches (510 mm). A wing wall may extend beyond the face of the telephone a maximum of 24 inches (610 mm). If the wing wall extends more than 24 inches (610 mm) beyond the face of the telephone, an additional 6 inches (150 mm) in width of clear floor space shall be provided.

Figure 44(b)

Forward Reach Required

4.31.3* MOUNTING HEIGHT.

The highest operable part of the telephone shall be within the reach ranges specified in 4.2.5 or 4.2.6.

4.31.4 PROTRUDING OBJECTS.

Telephones shall comply with 4.4.

4.31.5* EQUIPMENT FOR HEARING IMPAIRED PEOPLE.

Telephones shall be equipped with a receiver that generates a magnetic field in the area of the receiver cap. Volume controls shall be provided in accordance with 4.1.2.

4.31.6 CONTROLS.

Telephones shall have pushbutton controls where service for such equipment is available.

4.31.7 TELEPHONE BOOKS.

Telephone books, if provided, shall be located in a position that complies with the reach ranges specified in 4.2.5 and 4.2.6.

4.31.8 CORD LENGTH.

The cord from the telephone to the handset shall be at least 29 in (735 mm) long.