408.4 Elevator Cars.
Elevator cars shall comply with 408.4.
408.4.1 Car Dimensions and Doors.
Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a clear depth 54 inches (1370 mm) minimum. Car doors shall be positioned at the narrow ends of cars and shall provide 32 inches (815 mm) minimum clear width.
EXCEPTIONS: 1. Cars that provide a clear width 51 inches (1295 mm) minimum shall be permitted to provide a clear depth 51 inches (1295 mm) minimum provided that car doors provide a clear opening 36 inches (915 mm) wide minimum.
2. Existing elevator cars shall be permitted to provide a clear width 36 inches (915 mm) minimum, clear depth 54 inches (1370 mm) minimum, and a net clear platform area 15 square feet (1.4 m2) minimum.
408.4.2 Floor Surfaces.
Floor surfaces in elevator cars shall comply with 302 and 303.
408.4.3 Platform to Hoistway Clearance.
The platform to hoistway clearance shall comply with 407.4.3.
408.4.4 Leveling.
Elevator car leveling shall comply with 407.4.4.
408.4.5 Illumination.
Elevator car illumination shall comply with 407.4.5.
408.4.6 Car Controls.
Elevator car controls shall comply with 407.4.6. Control panels shall be centered on a side wall.
408.4.7 Designations and Indicators of Car Controls.
Designations and indicators of car controls shall comply with 407.4.7.
408.4.8 Emergency Communications.
Car emergency signaling devices complying with 407.4.9 shall be provided.