Hello. Please sign in!

2012 Texas Accessibility Standards (TAS) Pocket Guide

Note: This document or portion of document references a state or local code that aligns with the 2010 ADA Standards requirements.

1008.3.2 Transfer Steps.

Transfer steps shall be provided where movement is intended from transfer platforms to levels with elevated play components required to be on accessible routes. Transfer steps shall comply with 1008.3.2.

Figure (a) is an elevation drawing of a transfer step 8 inches (205 mm) high maximum.

(a)
elevation

Figure (b) is a plan view of a transfer step that is 14 inches (355 mm) deep minimum and 24 inches (610 mm) long minimum.

(b)
plan

Figure 1008.3.2 Transfer Steps 

1008.3.2.1 Size.

Transfer steps shall have level surfaces 14 inches (355 mm) deep minimum and 24 inches (610 mm) wide minimum.

1008.3.2.2 Height.

Each transfer step shall be 8 inches (205 mm) high maximum.

1008.3.2.3 Transfer Supports.

At least one means of support for transferring shall be provided.

Advisory 1008.3.2.3 Transfer Supports. Transfer supports are required on transfer platforms and transfer steps to assist children when transferring. Some examples of supports include a rope loop, a loop type handle, a slot in the edge of a flat horizontal or vertical member, poles or bars, or D rings on the corner posts.

[MORE INFO...]

*You must sign in to view [MORE INFO...]