219.3 Receivers.
Receivers complying with 706.2 shall be provided for assistive listening systems in each assembly area in accordance with Table 219.3. Twenty-five percent minimum of receivers provided, but no fewer than two, shall be hearing-aid compatible in accordance with 706.3.
EXCEPTIONS:
1. Where a building contains more than one assembly area and the assembly areas required to provide assistive listening systems are under one management, the total number of required receivers shall be permitted to be calculated according to the total number of seats in the assembly areas in the building provided that all receivers are usable with all systems.
2. Where all seats in an assembly area are served by an induction loop assistive listening system, the minimum number of receivers required by Table 219.3 to be hearing-aid compatible shall not be required to be provided.
Table 219.3 Receivers for Assistive Listening Systems
Capacity of Seating in Assembly Area |
Minimum Number of Required Receivers |
Minimum Number of Required Receivers Required to be Hearing-aid Compatible |
50 or less |
2 |
2 |
51 to 200 |
2, plus 1 per 25 seats over 50 seats¹ |
2 |
201 to 500 |
2, plus 1 per 25 seats over 50 seats¹ |
1 per 4 receivers¹ |
501 to 1000 |
20, plus 1 per 33 seats over 500 seats¹ |
1 per 4 receivers¹ |
1001 to 2000 |
35, plus 1 per 50 seats over 1000 seats¹ |
1 per 4 receivers¹ |
2001 and over |
55, plus 1 per 100 seats over 2000 seats¹ |
1 per 4 receivers¹ |
1Or fraction thereof.