224.2 Guest Rooms with Mobility Features.
In transient lodging facilities, guest rooms with mobility features complying with 806.2 shall be provided in accordance with Table 224.2.
EXCEPTIONS:
1. Facilities on a common site that each have 50 or fewer guest rooms may be combined for the purposes of determining the required number of accessible rooms and type of accessible bathing facility in accordance with table 224.2 to section 224.2.
2. Facilities with more than 50 guest rooms shall be treated separately for the purposes of determining the required number of accessible rooms and type of accessible bathing facility in accordance with table 224.2 to section 224.2.
Table 224.2 Guest Rooms with Mobility Features
Total Number of Guest Rooms Provided |
Minimum Number of Required Rooms Without Roll-In Showers |
Minimum Number of Required Rooms With Roll-In Showers |
Total Number of Required Rooms |
1 to 25 |
1 |
0 |
1 |
26 to 50 |
2 |
0 |
2 |
51 to 75 |
3 |
1 |
4 |
76 to 100 |
4 |
1 |
5 |
101 to 150 |
5 |
2 |
7 |
151 to 200 |
6 |
2 |
8 |
201 to 300 |
7 |
3 |
10 |
301 to 400 |
8 |
4 |
12 |
401 to 500 |
9 |
4 |
13 |
501 to 1000 |
2 percent of total |
1 percent of total |
3 percent of total |
1001 and over |
20, plus 1 for each 100, or fraction thereof, over 1000 |
10, plus 1 for each 100, or fraction thereof, over 1000 |
30, plus 2 for each 100, or fraction thereof, over 1000 |