Hello. Please sign in!

2012 Texas Accessibility Standards (TAS) Pocket Guide

Note: This document or portion of document references a state or local code that aligns with the 2010 ADA Standards requirements.

404.2.4.3 Recessed Doors and Gates.

Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches (455 mm) of the latch side of a doorway projects more than 8 inches (205 mm) beyond the face of the door, measured perpendicular to the face of the door or gate.

Advisory 404.2.4.3 Recessed Doors and Gates. A door can be recessed due to wall thickness or because of the placement of casework and other fixed elements adjacent to the doorway. This provision must be applied wherever doors are recessed.

Figure (a) shows front approach at doors recessed more than 8 inches (455 mm).  Maneuvering space on the pull side extends 18 inches (455 mm) minimum beyond the latch side of the door and 60 inches (1525 mm) minimum perpendicular to the plane of the doorway.

(a)
pull side

Figure (b) shows front approaches at doors recessed more than 8 inches (455 mm). On the push side of doors not equipped with a closer or latch, the maneuvering space is the same width as the door opening and extends 48 inches (1220 mm) minimum perpendicular to the plane of the doorway.

(b)
push side

Figure (c) shows front approach at doors recessed more than 8 inches (455 mm). On the push side of doors equipped with both a closer and a latch, the maneuvering space extends 12 inches (305 mm) minimum beyond the latch side of the door and 48 inches (1220 mm) minimum measured perpendicular to the plane of the doorway.

(c)
push side, door provided with both closer and latch

Figure 404.2.4.3 Maneuvering Clearances at Recessed Doors and Gates