2013 California Standards for Accessible Design Pocket Guide
11B-1008.2.5.3 Handrails.
Where required on ramps serving play components, the handrails shall comply with Section 11B-505 except as modified by Section 11B-1008.2.5.3.
Exceptions:
1. Handrails shall not be required on ramps located within ground level use zones.
2. Handrail extensions shall not be required.
11B-1008.2.5.3.1 Handrail gripping surfaces.
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum. Where the shape of the gripping surface is non-circular, the handrail shall provide an equivalent gripping surface.
11B-1008.2.5.3.2 Handrail height.
The top of handrail gripping surfaces shall be 20 inches (508 mm) minimum and 28 inches (711 mm) maximum above the ramp surface.