Note: This document or portion of document references a state or local code that is stricter than the 2010 ADA Standards requires.

11B-219.3 Receivers.

The minimum number of receivers to be provided shall be equal to 4 percent of the total number of seats, but in no case less than two. Twenty-five percent minimum of receivers provided, but no fewer than two, shall be hearing-aid compatible in accordance with Section 11B-706.3

[2010 ADAS] 219.3 Receivers.  Receivers complying with 706.2 shall be provided for assistive listening systems in each assembly area in accordance with Table 219.3. Twenty-five percent minimum of receivers provided, but no fewer than two, shall be hearing-aid compatible in accordance with 706.3.

Exceptions:

1.      Where a building contains more than one assembly area and the assembly areas required to provide assistive listening systems are under one management, the total number of required receivers shall be permitted to be calculated according to the total number of seats in the assembly areas in the building provided that all receivers are usable with all systems.

2.      Where all seats in an assembly area are served by an induction loop assistive listening system, the minimum number of receivers required by Section 11B-219.3 to be hearing-aid compatible shall not be required to be provided. 

[2010 ADAS] Table 219.3 Receivers for Assistive Listening Systems

Capacity of Seating in Assembly Area

Minimum Number of Required Receivers

Minimum Number of Required Receivers Required to be Hearing-aid Compatible

50 or less

2

2

51 to 200

2, plus 1 per 25 seats over 50 seats  1

2

201 to 500

2, plus 1 per 25 seats over 50 seats  1

1 per 4 receivers  1

501 to 1000

20, plus 1 per 33 seats over 500 seats  1

1 per 4 receivers  1

1001 to 2000

35, plus 1 per 50 seats over 1000 seats  1

1 per 4 receivers  1

2001 and over

55 plus 1 per 100 seats over 2000 seats  1

1 per 4 receivers  1