11B-224.2 Guest rooms with mobility features.
In transient lodging facilities, guest rooms with mobility features complying with Section 11B-806.2 shall be provided in accordance with Table 11B-224.2, as follows.
[2010 ADAS] 224.2 Guest Rooms with Mobility Features. In transient lodging facilities, guest rooms with mobility features complying with 806.2 shall be provided in accordance with Table 224.2.
11B-224.2.1 Fifty or less guest room facilities.
Facilities that are subject to the same permit application on a common site that each have fifty or fewer guest rooms may be combined for the purposes of determining the required number of accessible rooms and type of accessible bathing facility.
11B-224.2.2 More than fifty guest room facilities.
Facilities with more than fifty guest rooms shall be treated separately for the purposes of determining the required number of accessible rooms and type of accessible bathing facility.
GUEST ROOMS WITH MOBILITY FEATURES
TOTAL NUMBER OF GUEST ROOMS PROVIDED |
MINIMUM NUMBER OF REQUIRED ROOMS WITHOUT ROLL-IN SHOWERS |
MINIMUM NUMBER OF REQUIRED ROOMS WITH ROLL-IN SHOWERS |
TOTAL NUMBER OF REQUIRED ROOMS |
---|---|---|---|
1 to 25 |
0 [2010 ADAS] 1 |
1 [2010 ADAS] 0 |
1 |
26 to 50 |
1 [2010 ADAS] 2 |
1 [2010 ADAS] 0 |
2 |
51 to 75 |
3 |
1 |
4 |
76 to 100 |
4 |
1 |
5 |
101 to 150 |
5 |
2 |
7 |
151 to 200 |
6 |
2 |
8 |
201 to 300 |
7 |
3 |
10 |
301 to 400 |
8 |
4 |
12 |
401 to 500 |
9 |
4 |
13 |
501 to 1000 |
2 percent of total |
1 percent of total |
3 percent of total |
1001 and over |
20, plus 1 for each 100, or fraction thereof, over 1000 |
10, plus 1 for each 100, or fraction thereof, over 1000 |
30, plus 2 for each 100, or fraction thereof, over 1000 |
For example, a new 275-room hotel must have a total of ten mobility accessible guest rooms; a minimum of three of the ten must have roll-in showers per Table 11B-224.2. In addition to those ten mobility accessible rooms, 17 guest rooms are required to provide communication features per Table 11B-224.4. Only 10 percent of the rooms required to provide mobility features, or one mobility accessible room, may also be used to satisfy the requirements of Table 11B-224.4. Sixteen additional communication accessible rooms must be provided. ◼