Hello. Please sign in!

Note: This document or portion of document references a state or local code that aligns with the 2010 ADA Standards requirements.

11B-305.5 Position.

Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element.

For a forward approach to an element, a clear floor or ground space, 30 inches by 48 inches minimum, is shown with the shorter dimension parallel to the wall or element. For a parallel approach to an element, a clear floor or ground space, 30 inches by 48 inches minimum, is shown with the longer dimension parallel to the wall or element.

FIGURE 11B-305.5

POSITION OF CLEAR FLOOR OR GROUND SPACE

[MORE INFO...]

*You must sign in to view [MORE INFO...]