Hello. Please sign in!

Note: This document or portion of document references a state or local code that aligns with the 2010 ADA Standards requirements.

11B-404.2.11 Vision lights.

Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1092 mm) maximum above the finish floor.

Exception:  Glazing panels with the lowest part more than 66 inches (1676 mm) from the finish floor or ground shall not be required to comply with Section 11B-404.2.11.

ETA Editor's Note

The vision light requirement of 2013 CBC 11B-404.2.11 is new, derived from 2010 ADAS 404.2.11.  An existing door with a noncompliant vision light is a Safe Harbored element for path of travel and barrier removal purposes, but will have to comply when the door is replaced, and may not be relocated elsewhere on an accessible route.

[MORE INFO...]

*You must sign in to view [MORE INFO...]