11B-407.2.2.2 Visible signals.

Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground. The visible signal elements shall be a minimum 2½ inches (64 mm) high by 2½ inches (64 mm) wide. Signals shall be visible from the floor area adjacent to the hall call button.

Exceptions:

1.      Reserved.

2.      Reserved.

[2010 ADAS] 2.  Existing elevators shall not be required to comply with 407.2.2.2

Visible signals are shown centered at 72 inches minimum above the floor ground. The individual “up” and “down” elements, one with circular elements, another with triangular elements, are 2 1/2 inches minimum measured along the vertical and horizontal centerlines of the element.

FIGURE 11B-407.2.2.2 ‡‡

VISIBLE HALL SIGNALS