11B-608.5.2 Standard roll-in type shower compartments.

In standard roll-in type shower compartments, operable parts of controls and faucets shall be installed on the back wall of the compartment adjacent to the seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor, with their centerline at 39 inches (991 mm) to 41 inches (1041 mm) above the shower floor.

Operable parts of the shower spray unit, including the handle, shall be installed on the back wall adjacent to the seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor.

[2010 ADAS] 608.5.2 Standard Roll-In Type Shower Compartments.  In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor. Where a seat is provided, the controls, faucets, and shower spray unit shall be installed on the back wall adjacent to the seat wall and shall be located 27 inches (685 mm) maximum from the seat wall.

Figure (a) Reserved-Model Code Figure Not Applicable. Figure (b) is an elevation drawing of a compartment with a seat. The area for controls, faucets and shower spray units is located on the back wall 19" minimum and 27 inches maximum from the seat wall and above the grab bar, but no higher than 48 inches above the shower floor.

FIGURE 11B-608.5.2 ‡‡

STANDARD ROLL-IN TYPE SHOWER COMPARTMENT CONTROL LOCATION