11B-1009.5.7 Grab bars.

At least one grab bar on each transfer step and the transfer platform or a continuous grab bar serving each transfer step and the transfer platform shall be provided. Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (102 mm) minimum and 6 inches (152 mm) maximum above each step and transfer platform. Where a continuous grab bar is provided, the top of the gripping surface shall be 4 inches (102 mm) minimum and 6 inches (152 mm) maximum above the step nosing and transfer platform. Grab bars shall comply with Section 11B-609 and be located on at least one side of the transfer system. The grab bar located at the transfer platform shall not obstruct transfer.

Exception: Grab bars on transfer systems shall not be required to comply with Section11B-609.4.

Two elevation drawings show grab bars at transfer systems. Figure (a) shows individual grab bars on the platform and each step with the top of the gripping surface 4 to 6 inches above each step and transfer platform. Figure (b) shows a continuous grab bar with the top of the gripping surface 4 to 6 inches above the step nosing and transfer platform.

(a)
individual grab bars

Two elevation drawings show grab bars at transfer systems. Figure (a) shows individual grab bars on the platform and each step with the top of the gripping surface 4 to 6 inches above each step and transfer platform. Figure (b) shows a continuous grab bar with the top of the gripping surface 4 to 6 inches above the step nosing and transfer platform.

(b)
continuous grab bars

FIGURE 11B-1009.5.7
GRAB BARS