11B-213.3 Plumbing fixtures and accessories.

Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with Section 11B-213.2 shall comply with Section 11B-213.3.

dsa icon
 Advisory 11B-213.3 Plumbing fixtures and accessories.  The 2016 California Plumbing Code (CPC), Table 422.1 provides minimum plumbing fixture requirements for new buildings, and changes of occupancy or use in an existing building resulting in increased occupant load. CPC Table 422.1 should be consulted in conjunction with the requirements of this section. ◼

11B-213.3.1 Toilet compartments.

[2010 ADAS] 213.3.1 Toilet Compartments. Where toilet compartments are provided, at least one toilet compartment shall comply with 604.8.1. In addition to the compartment required to comply with 604.8.1, at least one compartment shall comply with 604.8.2 where six or more toilet compartments are provided, or where the combination of urinals and water closets totals six or more fixtures.

[2010 ADAS] Advisory 213.3.1 Toilet Compartments.  A toilet compartment is a partitioned space that is located within a toilet room, and that normally contains no more than one water closet. A toilet compartment may also contain a lavatory. A lavatory is a sink provided for hand washing. Full-height partitions and door assemblies can comprise toilet compartments where the minimum required spaces are provided within the compartment.  

ETA Editor’s Note:

The 2016 CBC includes scoping requirements for toilet compartments based on the total number of compartments and urinals provided. The CBC is more inclusive and will require more accessible toilet compartments in larger toilet rooms.

11B-213.3.2 Water closets.

[2010 ADAS] 213.3.2 Water Closets. Where water closets are provided, at least one shall comply with 604.

ETA Editor’s Note:

The 2016 CBC is more inclusive, requiring more accessible water closets in larger toilet rooms.

11B-213.3.3 Urinals.

[2010 ADAS] 213.3.3 Urinals. Where more than one urinal is provided, at least one shall comply with 605.

ETA Editor’s Note:

The 2016 CBC is more inclusive, requiring more accessible urinals in larger toilet rooms.

11B-213.3.4 Lavatories.

Where lavatories are provided, at least ten percent but no fewer than one shall comply with Section 11B-606 and shall not be located in a toilet compartment.

[2010 ADAS] 213.3.4 Lavatories. Where lavatories are provided, at least one shall comply with 606 and shall not be located in a toilet compartment.

ETA Editor’s Note

The 2016 CBC is more inclusive, requiring more accessible lavatories in larger toilet rooms.

ETA Editor's Note

With the revisions to scoping requirements in Subsections 11B-213.3.1 through 11B-213.3.4 implemented by the 2013 CBC Supplement dated July 1, 2015, DSA-AC has increased the number of accessible toilet compartments, ambulatory accessible toilet compartments, accessible urinals and accessible lavatories required at very large multi-user toilet rooms.  Since the CBC path of travel obligation to remove existing barriers only allows "safe harbor" dating back to the "immediately preceding edition" (see 11B-202.4, Exception 2), existing facilities having toilet rooms that do not comply with the increased scoping will be compelled by this obligation to upgrade these toilet rooms if alterations are performed to an area served by them.

11B-213.3.5 Mirrors.

Where mirrors are provided, at least one shall comply with Section 11B-603.3.

11B-213.3.6 Bathing facilities.

Where bathtubs or showers are provided, at least one bathtub complying with Section 11B-607 or at least one shower complying with Section 11B-608 shall be provided. Where two or more accessible showers are provided within the same functional area, at least one shower shall be opposite hand from the other or others (that is, one left-hand controls versus right-hand controls).

[2010 ADAS] 213.3.6 Bathing Facilities.  Where bathtubs or showers are provided, at least one bathtub complying with 607 or at least one shower complying with 608 shall be provided.

ETA Editor's Note

The ADA requirements included at Subsection 11B-213.3.6 are provided for information only. The CBC scoping requirements are more stringent, since they address not only the quantity of accessible showers, but also their orientation.  

11B-213.3.7 Coat hooks and shelves.

Where coat hooks or shelves are provided in toilet rooms without toilet compartments, at least one of each type shall comply with Section 11B-603.4. Where coat hooks or shelves are provided in toilet compartments, at least one of each type complying with Section 11B-604.8.3 shall be provided in toilet compartments required to comply with Section 11B-213.3.1. Where coat hooks or shelves are provided in bathing facilities, at least one of each type complying with Section 11B-603.4 shall serve fixtures required to comply with Section 11B-213.3.6