2016 California Standards for Accessible Design Pocket Guide - Eff. Jan. 1, 2017
11B-216.4 Means of egress.
Signs for means of egress shall comply with Section 11B-216.4.
11B-216.4.1 Exit doors.
Signs required by Chapter 10, Section 1013.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2 _|Signs; Raised Characters|_, 11B-703.3 _|Braille|_, and 11B-703.5 _|Signs; Visual Characters|_.
[2010 ADAS] Advisory 216.4.1 Exit Doors. An exit passageway is a horizontal exit component that is separated from the interior spaces of the building by fire-resistance-rated construction and that leads to the exit discharge or public way. The exit discharge is that portion of an egress system between the termination of an exit and a public way.
11B-216.4.2 Areas of refuge and exterior areas for assisted rescue.
Signs required by Chapter 10, Section 1009.11 to provide instructions in areas of refuge shall comply with Section 11B-703.5 _|Signs; Visual Characters|_. Signs required by Chapter 10, Section 1009.9 at doors to areas of refuge and exterior areas for assisted rescue shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2 _|Signs; Raised Characters|_, 11B-703.3 _|Braille|_, and 11B-703.5 and include an International Symbol of Accessibility complying with Section 11B-703.7.2.1.
11B-216.4.3 Directional signs.
Signs required by Chapter 10, Section 1009.10 to provide directions to accessible means of egress shall comply with Section 11B-703.5 _|Signs; Visual Characters|_.
11B-216.4.4 Delayed egress locks.
Signs required by Chapter 10, Section 1010.1.9.7, Item 6.4 at doors with delayed egress locks shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2 _|Signs; Raised Characters|_, 11B-703.3 _|Braille|_, and 11B-703.5 _|Signs; Visual Characters|_.