2016 California Standards for Accessible Design Pocket Guide - Eff. Jan. 1, 2017
11B-305 Clear floor or ground space.
11B-305.1 General.
Clear floor or ground space shall comply with Section 11B-305.
11B-305.2 Floor or ground surfaces.
Floor or ground surfaces of a clear floor or ground space shall comply with Section 11B-302. Changes in level are not permitted.
Exception: Slopes not steeper than 1:48 shall be permitted.
11B-305.3 Size.
The clear floor or ground space shall be 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum.
11B-305.4 Knee and toe clearance.
Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with Section 11B-306.
11B-305.5 Position.
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element.
11B-305.6 Approach.
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space. Clear floor or ground space may overlap an accessible route, unless specifically prohibited elsewhere in this chapter.
11B-305.7 Maneuvering clearance.
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with Sections 11B-305.7.1 and 11B-305.7.2.
11B-305.7.1 Forward approach.
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm).
11B-305.7.2 Parallel approach.
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm).