2016 California Standards for Accessible Design Pocket Guide - Eff. Jan. 1, 2017
11B-306.2 Toe clearance.
11B-306.2.1 General.
Space under an element between the finish floor or ground and 9 inches (229 mm) above the finish floor or ground shall be considered toe clearance and shall comply with Section 11B-306.2.
11B-306.2.2 Maximum depth.
Toe clearance shall extend 25 inches (635 mm) maximum under an element.
Exception: Toe clearance shall extend 19 inches (483 mm) maximum under lavatories required to be accessible by Section 11B-213.3.4.
11B-306.2.3 Minimum required depth.
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (432 mm) minimum under the element.
Exceptions:
11B-306.2.4 Additional clearance.
Space extending greater than 6 inches (152 mm) beyond the available knee clearance at 9 inches (229 mm) above the finish floor or ground shall not be considered toe clearance.
11B-306.2.5 Width.
Toe clearance shall be 30 inches (762 mm) wide minimum.
User Comments/Questions
Add Comment/Question