Hello. Please sign in!

Note: This document or portion of document references a state or local code that aligns with the 2010 ADA Standards requirements.

11B-308.3 Side reach.

11B-308.3.1 Unobstructed.

Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side reach shall be 15 inches (381 mm) minimum above the finish floor or ground. 

Exceptions:

1.     An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (254 mm) maximum.

2.     Operable parts of fuel dispensers shall be permitted to be 54 inches (1372 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs.  

The drawing shows a frontal view of a person using a wheelchair making a side reach to a wall. The depth of reach is 10 inches maximum. The vertical reach range is 15 inches minimum to 48 inches maximum.

FIGURE 11B-308.3.1
UNOBSTRUCTED SIDE REACH

11B-308.3.2 Obstructed high reach.

Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum and the depth of the obstruction shall be 24 inches (610 mm) maximum. The high side reach shall be 48 inches (1219 mm) maximum for a reach depth of 10 inches (254 mm) maximum. Where the reach depth exceeds 10 inches (254 mm), the high side reach shall be 46 inches (1168 mm) maximum for a reach depth of 24 inches (610 mm) maximum. 

Exceptions:

1.     The top of washing machines and clothes dryers shall be permitted to be 36 inches (914 mm) maximum above the finish floor.

2.     Operable parts of fuel dispensers shall be permitted to be 54 inches (1372 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs.

Figure (a) shows a person seated in a wheelchair reaching a point on a wall above a protrusion, such as a wall-mounted counter, which is 20 inches deep maximum. The maximum reach height is 48 inches. In figure (b), the obstruction is more than 20 inches deep, with 25 inches the maximum depth. The maximum reach height is 44 inches.

(a)

Figure (a) shows a person seated in a wheelchair reaching a point on a wall above a protrusion, such as a wall-mounted counter, which is 20 inches deep maximum. The maximum reach height is 48 inches. In figure (b), the obstruction is more than 20 inches deep, with 25 inches the maximum depth. The maximum reach height is 44 inches.

(b)

FIGURE 11B-308.3.2
OBSTRUCTED HIGH SIDE REACH

[MORE INFO...]

*You must sign in to view [MORE INFO...]