2016 California Standards for Accessible Design Pocket Guide - Eff. Jan. 1, 2017
11B-407.3.3 Reopening device.
Elevator doors shall be provided with a reopening device complying with Section 11B-407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed by an object or person.
Exception: Existing elevators with manually operated doors shall not be required to comply with Section 11B-407.3.3.
11B-407.3.3.1 Height.
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
11B-407.3.3.2 Contact.
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses.
11B-407.3.3.3 Duration.
Door reopening devices shall remain effective for 20 seconds minimum.
User Comments/Questions