Hello. Please sign in!

Note: This document or portion of document references a state or local code that is stricter than the 2010 ADA Standards requires.

11B-604.3.1 Size. Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall. A minimum 60 inches (1524 mm) wide and 48 inches (1219 mm) deep maneuvering space shall be provided in front of the water closet.

Exception: In residential dwelling units complying with Section 11B-233.3.1.1, maneuvering space in front of the water closet shall be a minimum 60 inches (1524 mm) wide and 36 inches (914 mm) deep.

[2010 ADAS] 604.3.1 Size. Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall.

ETA Editor's Note

The CBC 11B-604.3 requirement for clearance in front of accessible water closets exceeds the 2010 ADAS requirement, but a door may swing into the added clearance.

The clearance around a water closet is shown in plan view to be 60 inches wide minimum and 56 inches deep minimum with additional maneuvering space in front of the water closet clear floor space, in which a door is permitted to swing over.

FIGURE 11B-604.3.1 ‡‡
SIZE OF CLEARANCE AT WATER CLOSETS

[MORE INFO...]

*You must sign in to view [MORE INFO...]