Note: This document or portion of document references a state or local code that is stricter than the 2010 ADA Standards requires.

11B-608.2 Size and clearances for shower compartments. Shower compartments shall have sizes and clearances complying with Section 11B-608.2.

11B-608.2.1 Reserved.

ETA Editor's Note

The transfer type shower compartments prescribed by 2010 ADAS 608.2.1 are not recognized as an accessible shower in California.

11B-608.2.2 Standard roll-in type shower compartments. Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides with a full opening width on the long side.

[2010 ADAS] 608.2.2 Standard Roll-In Type Shower Compartments. Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides and shall have a 60 inches (1525 mm) wide minimum entry on the face of the shower compartment.

A plan view shows the shower compartment is 30 inches minimum by 60 inches minimum with a 60 inch wide entry on the face of the compartment. A clear floor space 36 inches side is provided adjacent to the open face of the compartment. A seat is shown on one end.

Note: inside finished dimensions measured at the center points of opposing sides.

FIGURE 11B-608.2.2 ‡‡
STANDARD ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE

11B-608.2.2.1 Clearance. A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment.

[2010 ADAS] 608.2.2.1 Clearance. A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment.

Exception: Reserved.

[2010 ADAS] EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance adjacent to the controls or, where provided, not on the side of the clearance adjacent to the shower seat.

11B-608.2.3 Alternate roll-in type shower compartments. Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides. A 36 inch (914 mm) wide minimum entry shall be provided at one end of the long side of the compartment.

 A plan view shows the shower compartment is 36 inches wide absolute and 60 inches deep minimum. A 36 inch wide minimum entry is provided on one long wall. A seat is provided adjacent to the entry on the same wall.

Note: inside finished dimensions measured at the center points of opposing sides.

FIGURE 11B-608.2.3
ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE