11B-803.1 General.
Dressing, fitting, and locker rooms shall comply with Section 11B-803.
11B-803.2 Turning space.
Turning space complying with Section 11B-304 shall be provided within the room.
11B-803.3 Door swing.
Doors shall not swing into the room unless a turning space complying with Section 11B-304.3 is provided beyond the arc of the door swing.
11B-803.4 Benches.
A bench complying with Section 11B-903 shall be provided within the room.
11B-803.5 Coat hooks and shelves.
Coat hooks provided within the room shall be located within one of the reach ranges specified in Section 11B-308. Shelves shall be 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor or ground. Coat hooks shall not be located above the bench or other seating in the room.
[2010 ADA Standards] 803.5 Coat Hooks and Shelves. Coat hooks provided within the room shall be located within one of the reach ranges specified in 308. Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground.
11B-803.6 Mirrors.
Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground. Mirrors shall be full length with a reflective surface 18 inches (457 mm) wide minimum by 54 inches (1372 mm) high minimum and shall be mounted in a position affording a view to a person on the bench as well as to a person in a standing position.