Hello. Please sign in!

Note: This document or portion of document references a state or local code that aligns with the 2010 ADA Standards requirements.

11B-505.4 Height.

Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces. Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces.

DOJ icon
Advisory 11B-505.4 Height. The requirements for stair and ramp handrails in this chapter are for adults. When children are the principal users in a building or facility (e.g., elementary schools), a second set of handrails at an appropriate height can assist them and aid in preventing accidents. A maximum height of 28 inches (710 mm) measured to the top of the gripping surface from the ramp surface or stair nosing is recommended for handrails designed for children. Sufficient vertical clearance between upper and lower handrails, 9 inches (230 mm) minimum, should be provided to help prevent entrapment. 
Figure (a) shows stairs with the top gripping surface of a handrail 34 to 38 inches above stair nosings.
Figures (b) and (c) show ramps and walking surfaces, respectively. The top gripping surface of a handrail is 34 to 38 inches above the surface.
Figures (b) and (c) show ramps and walking surfaces, respectively. The top gripping surface of a handrail is 34 to 38 inches above the surface.

FIGURE 11B-505.4 HANDRAIL HEIGHT

[MORE INFO...]