Requirement 5. Light switches, electrical outlets, thermostats and other environmental controls in accessible locations.

Section 100.205(c)(3)(ii) requires that all covered multifamily dwellings with a building entrance on an accessible route shall be designed and constructed in such a manner that all premises within covered multifamily dwelling units contain light switches, electrical outlets, thermostats, and other environmental controls in accessible locations.

Guideline

Light switches, electrical outlets, thermostats and other environmental controls would meet section 100.205(c)(3)(ii) if operable parts of the controls are located no higher than 48 inches, and no lower than 15 inches, above the floor. If the reach is over an obstruction (for example, an overhanging shelf) between 20 and 25 inches in depth, the maximum height is reduced to 44 inches for forward approach; or 46 inches for side approach, provided the obstruction (for example, a kitchen base cabinet) is no more than 24 inches in depth. Obstructions should not extend more than 25 inches from the wall beneath a control. (See Fig.2.)

Note

Controls or outlets that do not satisfy these specifications are acceptable provided that comparable controls or outlets (i.e., that perform the same functions) are provided within the same area and are accessible, in accordance with this guideline for Requirement 5.

Two diagrams: Side elevation showing forward reach limit 15 min to 48 AFF; and plan view showing 30 x 48 wheelchair space.

(a) Forward Reach Limit

Two diagrams: Side elevation showing maximum forward reach over an obstruction as 44 when the obstruction is 20-25 deep and 48 high when the obstructions is 0-20 deep; and a plan view showing 30 x 48 wheelchair space extending under 25 max depth obstruction.

NOTE: Clear knee space should be as deep as the reach distance.

(b) Maximum Forward Reach Over an Obstruction

Front elevation showing maximum side reach over an obstruction as 46 when the obstruction is 24 deep and 34 max high AFF. Also 30 wide wheelchair space is shown adjacent to the surface.

(c) Maximum Side Reach Over Obstruction

Fig. 2 Reach Ranges