36 CFR Part 1190, Proposed Accessibility Guidelines for Pedestrian Facilities in the Public Right-of-Way: Notice of Proposed Rulemaking (NPRM)
R407 Ramps
R407.1 General. Ramps shall comply with R407.
R407.2 Running Slope. Ramp runs shall have a running slope between 5 percent minimum and 8.3 percent maximum.
R407.3 Cross Slope. The cross slope of ramp runs shall be 2 percent maximum.
R407.4 Width. The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 915 mm (3.0 ft) minimum.
R407.5 Rise. The rise for any ramp run shall be 760 mm (2.5 ft) maximum.
R407.6 Landings. Ramps shall have landings at the top and the bottom of each ramp run. Landings shall comply with R407.6.
R407.6.1 Slope. Landing slopes shall be 2 percent maximum in any direction.
R407.6.2 Width. The landing clear width shall be at least as wide as the widest ramp run leading to the landing.
R407.6.3 Length. The landing clear length shall be 1.5 m (5.0 ft) long minimum.
R407.6.4 Change in Direction. Ramps that change direction between runs at landings shall have a clear landing 1.5 m (5.0 ft) minimum by 1.5 m (5.0 ft) minimum.
R407.7 Surfaces. Surfaces of ramp runs and landings shall comply with R302.7.
R407.8 Handrails. Ramp runs with a rise greater than 150 mm (6 in) shall have handrails complying with R409.
R407.9 Edge Protection. Edge protection complying with R407.9.1 or R407.9.2 shall be provided on each side of ramp runs and ramp landings.
R407.9.1 Extended Ramp Surface. The surface of the ramp run or landing shall extend 305 mm (1.0 ft) minimum beyond the inside face of a handrail complying with R409.
R407.9.2 Curb or Barrier. A curb or barrier shall be provided that prevents the passage of a 100 mm (4 in) diameter sphere, where any portion of the sphere is within 100 mm (4 in) of the finish surface.