407.12.3.2 Obstructed Forward Reach (Section-by-Section Analysis)

This section proposes that, where an obstructed forward reach is provided, the maximum allowable forward reach to an operable part would be 25 inches. An obstructed forward reach, for purposes of this section, occurs when the operable part is located behind the leading edge of the maximum protrusion within the length of the vertical reference plane of the ICT. In addition, this proposed section also contains subsections, as discussed below, establishing maximum heights for operable parts with obstructed forward reaches, as well as dimensions for knee and toe spaces. These dimensions and their resulting geometry are consistent with the ADA and ABA Accessibility Guidelines (36 CFR Part 1191, Appendix D, sections 306 and 308).

407.12.3.2.1 Height (Section-by-Section Analysis)

This section, presented in tabular form (Table 407.12.3.2.1), proposes alternative maximum heights for operable parts with obstructed forward reaches depending on reach depth. As specified in this table, if the reach depth of the operable part is less than 20 inches, then the operable part must be no higher than 48 inches. If the reach depth of the operable part is 20 inches to 25 inches, then the operable part must be no higher than 44 inches. These dimensions and their resulting geometry are consistent with the ADA and ABA Accessibility Guidelines (36 CFR Part 1191, Appendix D, sections 306 and 308).

407.12.3.2.2 Knee and Toe Space (Section-by-Section Analysis)

This section proposes dimensions for knee and toe space under ICT when an obstructed forward reach is provided. The dimensions necessary to accommodate the full knee and toe space under ICT would be 27 inches high minimum, 25 inches deep maximum, and 30 inches wide minimum. This knee and toe space would also have to be clear of obstructions. These dimensions and their resulting geometry are consistent with the ADA and ABA Accessibility Guidelines (36 CFR Part 1191, Appendix D, sections 306 and 308).

There are two proposed exceptions to this knee and toe space requirement. First, toe space with a reduced clear height of 9 inches (rather than 27 inches) would be permitted for a depth of no more than 6 inches. Building on this exception, the second exception would allow further reduction in the height of the space along the profile of the knee to the toe sloping at 6:1 toward the maximum protrusion of the ICT. This means that, for every 6 inches of height, the line can move toward the maximum protrusion of the ICT up to 1 inch or, put another way, 6 inches of rise to 1 inch of run. These two exceptions allow ICT to provide space beneath operable controls for ICT for knees and toes, or a portion of knees and toes, depending on the location of the controls.