605 Urinals

605.1 General.

Urinals shall comply with 605.

Advisory 605.1 General. Stall-type urinals provide greater accessibility for a broader range of persons, including people of short stature.

605.2 Height and Depth.

Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (430 mm) maximum above the finish floor or ground. Urinals shall be 13½ inches (345 mm) deep minimum measured from the outer face of the urinal rim to the back of the fixture. [ECTCR UFAS 4.18.2]

Figure (a) is an elevation drawing of a wall hung type having the urinal rim 17 inches (430 mm) maximum above the floor with a minimum depth of 13½ inches (350 mm) measured from the outer face of the rim to the back of the fixture.
Figure (b) is an elevation drawing of a stall (floor) type having a minimum depth of 13½ inches (350 mm) measured from the outer face of the rim to the back of the fixture.

Figure 605.2 Height and Depth of Urinals

605.3 Clear Floor Space.

A clear floor or ground space complying with 305 positioned for forward approach shall be provided. [ECTCR UFAS 4.18.3]

605.4 Flush Controls.

Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with 309.