36 CFR Parts 1190 and 1191 ADA and ABA Accessibility Guidelines - Preamble (Discussion of Comments and Changes)
Comment. Comments advised revising requirements for unisex toilet and bathing rooms for greater consistency with model building codes. Recommendations also noted that unisex facilities are also referred to as "single use" or "family" toilet and bathing rooms in some codes.
Response. The requirements for unisex facilities have been revised according to specifications in the model building codes (213.2.1). Unisex toilet rooms must have a lavatory and privacy latch and cannot have more than two toileting fixtures (i.e., two water closets, or one water closet and one urinal). This differs from the proposed rule which required unisex toilet rooms to have one water closet. Unisex bathrooms must have a lavatory, water closet, privacy latch, and one shower, and may have a tub in addition to a shower. The proposed rule permitted either a shower or tub. The final rule also includes a reference indicating that unisex toilet and bathing rooms are also known as "single use or family" facilities.