36 CFR Parts 1190 and 1191 ADA and ABA Accessibility Guidelines - Preamble (Discussion of Comments and Changes)

Comment. In transfer compartments, controls, faucets, and shower spray units were to be located no more than 15 inches on either side of the seat centerline, according to the proposed rule (608.5.1). Comments indicated that this specification was not consistent with a corresponding figure showing the location on the side closest to the shower opening.

Response. The final rule has been revised to require that controls and operable parts be located 15 inches maximum from the centerline of the seat toward the shower opening. This is consistent with the intent of the specification so that users can activate the controls before entering the shower.