1. If there are more than 50 guestrooms/suites in the facility, are the proper number of accessible rooms with roll-in showers provided per table 9.1.2 below. (Note: accessible rooms with roll-in showers must be provided in addition to standard accessible guestrooms/suites.) [ADA Stds. 9.1.2]
Yes __ No __ N/A __ Comments: _____________________________________
(Table 9.1.2) | ||
Column "A" | Column "B" | |
Total Rooms in Facility | Accessible Rooms | Rooms with Roll-in Showers |
1 to 25 | 1 | 0 |
26 to 50 | 2 | 0 |
51 to 75 | 3 | 1 |
76 to 100 | 4 | 1 |
101 to 150 | 5 | 2 |
151 to 200 | 6 | 2 |
201 to 300 | 7 | 3 |
301 to 400 | 8 | 4 |
401 to 500 | 9 | See below* |
501 to 1000 | 2% of total rooms | See below* |
1001+ | 20 + (1 per 100 over 1000) | See below* |
Note: The number of accessible guest rooms for a given number of rooms in a hotel (left column) is derived by adding together column "A" and column "B". | ||
* the number of roll-in shower rooms in hotels with more than 400 guestrooms total equals 4 + (1 per 100 rooms over 400). |
User Comments/Questions
Add Comment/Question