Drawing Notes:

1. Faucets: Faucet handles or controls need to be usable with one loosely closed fist, because some people with disabilities can use only one hand and cannot grasp or twist faucets. Lever-operated, push-type mechanisms, and U-shaped handles are acceptable designs.

2. Mirrors: If provided, mirrors need to be mounted with the bottom edge of the reflecting surface no higher than 40 inches above the floor.

3. Lavatory knee clearance: To allow persons who use wheelchairs to pull under the lavatory and to use the faucet hardware, the following features need to be provided -- a 29-inch-high clearance under the front edge of the lavatory, the top of the bowl mounted no higher than 34 inches above the floor, a 27-inch-high clearance for knee space extending at least 8 inches from the front of the lavatory, and a 9-inch-high toe space extending not more than 6 inches from the back wall.

4. Burn protection: To protect against leg burns, hot water and drain pipes need to be covered or otherwise configured to protect against contact. Some people with disabilities have little or no sensation in their legs and can be burned without knowing it.

5. Clear floor space is needed for a forward approach to the lavatory.