TRANSFER STALLS

Size and Clearances [4.21.2]

Clear floor space is specified for side transfers. Where a forward approach is provided, space at least 60 inches wide provides room for turning. Recommendations: Consider additional clear floor space beyond the control wall to facilitate the reach to controls. (Where a row of stalls is provided, avoid locating accessible stalls in corners).

The 36 by 36 inch dimension, measured to the interior finish, keeps front and side grab bars within reach from the seat. Grab bars are configured so they do not interfere with use of the seat.

Plan diagram showing the required clear floor space adjacent to the shower entry for transfer

Seat [4.21.3]

ADAAG specifies maximum seat dimensions. Minimum dimensions contained in the CABO-ANSI A117.1‒1992 standard are acceptable. The seat must extend the full depth of the transfer stall to help minimize the gap between the seat and a wheelchair. Folding seats can be used.

Plan diagram showing shower seat requirements

Curbs [4.21.7]

Curbs are limited to ½ inch (measured from the room floor and the shower floor) so as not to interfere with entry to the shower. This height limit also allows wheelchair footrests to clear the curb so that a person using a wheelchair can partially pull into the stall for transfer to the seat.