EXTERIOR ROUTES |
|
Floor and ground surfaces stable, firm and slip resistant. |
|
Openings in floor or ground surfaces 1/2 inch maximum with long dimension perpendicular to direction of travel. |
|
Vertical change in level 1/4 inch high maximum. |
|
Changes in level greater than 1/2 inch ramped. |
|
Abrupt changes in level exceeding 4 inches, vertical dimension shall be identified by warning curb. |
|
Running and cross slopes at walking surfaces. Walks, sidewalks and ramps. |
|
Vertical clearances/protrusions along circulation paths. |
|
Site arrival points. An accessible route from parking, passenger loading zones, public streets and sidewalks to building entrance or facility. |
|
Within a site. One accessible route connecting accessible buildings, accessible facilities, accessible elements, and accessible spaces. |
|
Location of accessible routes coincides with general circulation paths. |
|
Clear width of walking surface. |
|
Contrasting stripe on upper approach and all treads. |
|
No open risers on stairways. |
|
Handrails on ramps and stairways. |
|
Curb ramps, blended transitions and islands. |
|
Raised islands in crossings shall be cut through level with the street or have curb ramps at both sides. | 11B-406.6 |
Installation and color of required detectable warnings. | 11B-705 |
Passing spaces along accessible routes with a clear width less than 60 inches. | 11B-403.5.3 |
Walks with continuous gradients have resting areas. |
11B-403.7 |
User Comments/Questions