Error/Omission:
In hotels, motels, or other lodging facilities of 50 or more sleeping rooms, no rooms with roll-in showers are provided, or the roll-in showers that are provided lack a fold-down seat.
Result:
People who must use a roll-in shower or a shower with a fold-down seat cannot bathe. When a roll-in shower is provided without a folding seat, guests may resort to using guest room furniture in the shower.
Requirement:
9.1.2 Accessible Units, Sleeping Rooms, and Suites. Accessible sleeping rooms or suites that comply with the requirements of 9.2 (Requirements for Accessible Units, Sleeping Rooms, and Suites) shall be provided in conformance with the table below. In addition, in hotels, of 50 or more sleeping rooms or suites, additional accessible sleeping rooms or suites that include a roll-in shower shall also be provided in conformance with the table below. Such accommodations shall comply with the requirements of 9.2, 4.21, and Figure 57(a) or (b).
Error/Omission:
Wheelchair-accessible rooms are not equipped with visual alarms and notification devices.
Result:
People who are deaf or hard of hearing and who also need to use a guest room with accessible features have no accommodation.
Requirement:
9.2.2 (8) Sleeping room accommodations for persons with hearing impairments required by 9.1 and complying with 9.3 shall be provided in the accessible room or suite.
Error/Omission:
Doors into and within guest rooms that are not accessible guest rooms do not provide at least 32" clear opening width.
Result:
People who use a wheelchair, scooter, or walker are unable to enter standard guest rooms and are excluded from accommodations when accessible guestrooms are occupied.
Requirement:
9.4 Other Sleeping Rooms and Suites. Doors and doorways designed to allow passage into and within all sleeping units or other covered units shall comply with 4.13.5.