Plan 1A: 13-Foot Wide Accessible Guest Room

This drawing shows an accessible 13-foot wide guest room with features that comply with the 2010 Standards. Features include a standard bathtub with a seat, comparable vanity, clothes closet with swinging doors, and door connecting to adjacent guest room. Furnishings include a king bed and additional seating.

Unidentified GIF image

 

The following accessible features are provided in the bathroom:

• Comparable vanity counter top space (section 806);

• Bathtub with a lavatory at the control end (section 607.2);

• Removable bathtub seat (section 607.3);

• Clearance in front of the bathtub extends its full length and is 30 inches wide min. (section 607.2);

• Recessed bathtub location permits shorter rear grab bar at water closet (section 604.5.2);

• Circular turning space in room (section 603.2.1);

• Required clear floor spaces at fixtures and turning space overlap (section 603.2.2);

• Turning space includes knee and toe clearance at lavatory (section 304.3);

• Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3);

• Centerline of the water closet at 16‒18 inches from side wall (section 604.2); and

• No other fixtures or obstructions located within required water closet clearance (section 604.3).

 

The following accessible features are provided in the living area:

• T-shaped turning space (section 304.3.2);

• Accessible route (section 402);

• Clear floor space on both sides of the bed (section 806.2.3);

• Maneuvering clearances at all doors (section 404.2);

• Accessible operable window (section 309); and

• Accessible controls for the heat and air conditioning (section 309).