II-6.3000 Major differences between ADAAG and UFAS.
II−6.3000 Major differences between ADAAG and UFAS. Set forth below is a summary of some of the major differences between ADAAG and UFAS.
II−6.3100 General principles
1) Work areas
ADAAG: Requires that areas used only by employees as work areas be designed and constructed so that individuals with disabilities can approach, enter, and exit the areas. There is, then, only a limited application of the standards to work areas (§4.1.1(3)).
UFAS: Contains no special limited requirement for work areas. The UFAS standards apply (as provided in the Architectural Barriers Act) in all areas frequented by the public or which "may result in employment ... of physically handicapped persons" (§1).
2) Equivalent facilitation
ADAAG: Departures from particular standards are permitted where alternatives will provide substantially equivalent or greater access (§2.2).
UFAS: UFAS itself does not contain a statement concerning equivalent facilitation. However, section 504 regulations, as well as the Department's title II regulation (28 CFR 35.151(c)), state that departures are permitted where it is "clearly evident that equivalent access" is provided.
3) Exemption from application of standards in new construction ADAAG: Contains a structural impracticability exception for new construction: full compliance with the new construction standards is not required in the rare case where the terrain prevents compliance (§4.1.1(5)(a)).
UFAS: Does not contain a structural impracticability exception (or any other exception) for new construction.
4) Exemption from application of standards in alterations ADAAG: For alterations, application of standards is not required where it would be "technically infeasible" (i.e., where application of the standards would involve removal of a load-bearing structural member or where existing physical or site restraints prevent compliance). Cost is not a factor (§4.1.6(1)(j)).
UFAS: Application of standards is not required for alterations where "structurally impracticable," i.e., where removal of a load-bearing structural member is involved or where the result would be an increased cost of 50 percent or more of the value of the element involved (§§4.1.6(3); 3.5 ("structural impractibility")). Cost is a factor. (Note that the similar term, "structural impracticability," is used in ADAAG (see item #3 above), but in ADAAG it is used in relation to new construction. In UFAS, it is used in relation to alterations, and it has a different meaning.)
5) Alterations triggering additional requirements
ADAAG: Alterations to primary function areas (where major activities take place) trigger a "path of travel" requirement, that is, a requirement to make the path of travel from the entrance to the altered area -- and telephones, restrooms, and drinking fountains serving the altered area -- accessible (§4.1.6(2)). But, under the Department of Justice title III rule, a public entity is not required to spend more than 20% of the cost of the original alteration on making the path of travel accessible, even if this cost limitation results in less than full accessibility (28 CFR 36.403(f)).
UFAS: If a building undergoes a "substantial alteration" (where the total cost of all alterations in a 12-month period amounts to 50% or more of the value of the building), the public entity must provide an accessible route from public transportation, parking, streets, and sidewalks to all accessible parts of the building; an accessible entrance; and accessible restrooms (§4.1.6(3)).
6) Additions
ADAAG: Each addition to an existing building is regarded as an alteration subject to the ADAAG alterations requirements (including triggering of path of travel obligations, if applicable). If the addition does not have an accessible entrance, the path of travel obligation may require an accessible route from the addition through the existing building, including its entrance and exterior approaches, subject to the 20% disproportionality limitation. Moreover, to the extent that a space or element is newly constructed as part of an addition, it is also regarded as new construction and must comply with the applicable new construction provisions of ADAAG (§4.1.5).
UFAS: Has specific requirements for additions, including requirements for entrances, routes, restrooms, and common areas. An accessible route from the addition through the existing building, including its entrance, is required if the addition does not have an accessible entrance (§4.1.5).
II-6.3200 Elements.
II-6.3200 Elements. The following requirements apply in new construction, unless otherwise indicated.
1) Van parking.
1) Van parking
ADAAG: One in every eight accessible spaces must be wide enough and high enough for a van lift to be deployed. The space must be marked as "van accessible" with a supplementary sign. Alternatively, "universal parking" is permitted, in which all spaces can accommodate van widths (§4.1.2(5)(b)). UFAS: Van parking is not required. Universal parking is not addressed.
2) Valet parking
ADAAG: Facilities with valet parking must have an accessible passenger loading zone on an accessible route to the exterior of the facility (§4.1.2(5)(e)).
UFAS: No requirements for valet parking.
3) Signs
ADAAG:
* Signs designating permanent rooms and spaces (men's and women's rooms; room numbers; exit signs) must have raised and Brailled letters; must comply with finish and contrast standards; and must be mounted at a certain height and location (§4.1.3(16)(a)).
* Signs that provide direction to or information about functional spaces of a building (e.g. "cafeteria this way;" "copy room") need not comply with requirements for raised and Brailled letters, but they must comply with requirements for character proportion, finish, and contrast. If suspended or projected overhead, they must also comply with character height requirements (§4.1.3(16)(b)).
* Building directories and other signs providing temporary information (such as current occupant's name) do not have to comply with any ADAAG requirements (§4.1.3(16)).
* Has requirements not only for the standard international symbol of accessibility, but also for symbols of accessibility identifying volume control telephones, text telephones, and assistive listening systems (§§4.1.2(7); 4.30.7).
UFAS:
* Signs designating permanent rooms and spaces must be raised (Braille is not required) and must be mounted at a certain height and location (§4.1.2(15)).
* All other signs (including temporary signs) must comply with requirements for letter proportion and color contrast, but not with requirements for raised letters or mounting height (§4.1.2(15)).
* Requires only the standard international symbol of accessibility (§4.30.5).
4) Entrances
ADAAG: At least 50 percent of all public entrances must be accessible with certain qualifications. In addition, there must be accessible entrances to enclosed parking, pedestrian tunnels, and elevated walkways (§4.1.3(8)).
UFAS: At least one principal entrance at each grade floor level must be accessible. In addition, there must be an accessible entrance to transportation facilities, passenger loading zones, accessible parking, taxis, streets, sidewalks, and interior accessible areas, if the building has entrances that normally serve those functions (§4.1.2(8)) . (This latter requirement could result in all entrances having to be accessible in many cases.)
5) Areas of rescue assistance or places of refuge ADAAG: Areas of rescue assistance (safe areas in which to await help in an emergency) are generally required on each floor, other than the ground floor, of a multistory building. An accessible egress route or an area of rescue assistance is required for each exit required by the local fire code. Specific requirements are provided for such features as location, size, stairway width, and two-way communications. Areas of rescue assistance are not required in buildings with supervised automatic sprinkler systems, nor are they required in alterations (§4.1.3(9)).
UFAS: Accessible routes must serve as a means of egress or connect to an accessible "place of refuge." No specific requirements for places of refuge are included. Rather, UFAS refers to local administrative authority for specific provisions on location, size, etc. UFAS requires more than one means of accessible egress when more than one exit is required (§4.3.10).
6) Water fountains
ADAAG: Where there is more than one fountain on a floor, 50% must be accessible to persons using wheelchairs. If there is only one drinking fountain on a floor, it must be accessible both to individuals who use wheelchairs and to individuals who have trouble bending or stooping (for example, a "hi-lo fountain" or fountain and water cooler may be used) (§4.1.3(10)). UFAS: Approximately 50% on each floor must be accessible. If there is only one fountain on a floor, it must be accessible to individuals who use wheelchairs (§4.1.3(9)).
7) Storage and shelves
ADAAG: One of each type of fixed storage facility must be accessible. Self-service shelves and displays must be on an accessible route but need not comply with reach-range requirements (§4.1.3(12)).
UFAS: Has the same requirements as ADAAG for fixed storage, but does not contain the reach requirement exemption for self-service shelves and displays (§4.1.2(11)).
8) Volume controls
ADAAG: All accessible public phones must be equipped with volume controls. In addition, 25%, but never less than one, of all other public phones must have volume controls (§4.1.3(17)(b)).
UFAS: At least one accessible telephone must have a volume control (§4.1.2(16)(b)).
9) Telecommunication Devices for the Deaf (TDD's)
ADAAG: One TDD (also known as a "text telephone") must be provided inside any building that has at least one interior pay phone and four or more public pay telephones, counting both interior and exterior phones. In addition, one TDD or text telephone (per facility) must be provided whenever there is an interior public pay phone in a stadium or arena; convention center; hotel with a convention center; covered shopping mall; or hospital emergency, recovery, or waiting room (§4.1.3(17)(c)).
UFAS: No requirement for TDD's.
10) Assembly areas
ADAAG:
* Wheelchair seating: Requirements triggered in any assembly area with fixed seating that seats four or more people. The number of wheelchair locations required depends upon the size of the assembly area. When the area has over 300 seats, there are requirements for dispersal of wheelchair seating. ADAAG also contains requirements for aisle seats without armrests (or with removable armrests) and fixed seating for companions located adjacent to each wheelchair seating area (§4.1.3(19)(a)).
* Assistive listening systems: Certain fixed seating assembly areas that accommodate 50 or more people or have audio-amplification systems must have permanently installed assistive listening systems. Other assembly areas must have permanent systems or an adequate number of electrical outlets or other wiring to support a portable system. A special sign indicating the availability of the system is required. The minimum number of receivers must be equal to four percent of the total number of seats, but never less than two (§4.1.3(19)(b)). UFAS:
* Wheelchair seating: No requirements for wheelchair seating are triggered, unless the assembly area has 50 or more seats. Seating must be dispersed and provide comparable lines of sight (§4.1.2(18)(a)).
* Assistive listening systems: Assembly areas with audio-amplification systems must have a listening system that serves a reasonable number of people, but at least two. If it has no amplification system or is used primarily as meeting or conference room, it must have a permanent or portable system. No special signs are required (§4.1.2(18)(b)).
11) Automated teller machines (ATM's)
ADAAG: Where ATM's are provided, each must be accessible, except that only one need comply when two or more ATM's are at the same location. Accessible machines must have, among other features, accessible controls and instructions and other information accessible to persons with sight impairments (§4.1.3(20)).
UFAS: No requirements for ATM's.
12) Bathrooms
ADAAG: Every public and common use bathroom must be accessible. Generally only one stall must be accessible (standard five-by-five feet). When there are six or more stalls, there must be one accessible stall and one stall that is three feet wide (§§4.1.3(11); 4.22.4).
UFAS: Same general requirements but no requirement for an additional three-foot-wide stall (§§4.1.2(10); 4.22.4).
13) Detectable warnings
ADAAG: Required on curb ramps, hazardous vehicular areas, and reflecting pools, but not on doors to hazardous areas. The warnings must be truncated domes (§4.29).
UFAS: "Tactile warnings" (uses different terminology) required only on doors to hazardous areas. Must be a textured surface on the door handle or hardware (§4.29).
14) Carpet and carpet tile
ADAAG: Same standards for carpet and carpet tile: maximum pile height of 1/2" (§4.5.3).
UFAS: Carpet must have maximum pile height of 1/2". Carpet tile must have maximum combined thickness of pile, cushion, and backing height of 1/2" (§4.5.3).
15) Curb ramps
ADAAG: Curb ramps must have detectable warnings (which must be raised truncated domes) (§4.7.7).
UFAS: No requirement for detectable warnings on curb ramps.
16) Elevator hoistway floor designations and car controls
ADAAG: Must have raised and brailled characters (§§4.10.5; 4.10.12).
UFAS: Must have raised characters; no requirement for Braille (§§4.10.5; 4.10.12).
17) Visual alarms
ADAAG: Contains details about features required on visual alarms for individuals with hearing impairments, including type of lamp, color, intensity, and location. Flash rate must be at a minimum of 1Hz and maximum of 3Hz (§4.28.3).
UFAS: Contains much less detail. Allows faster flash rate of up to 5Hz (§4.28.3).
18) Elevators and platform lifts in new construction and alterations
ADAAG: The elevator exemption for two-story places of public accommodation or commercial facilities does not apply to buildings and facilities subject to title II. Therefore, elevators are required in all new multilevel buildings or facilities, but vertical access to elevator pits, elevator penthouses, mechanical rooms, and piping or equipment catwalks is not required. Platform lifts may be used instead of elevators under certain conditions in new construction and may always be used in alterations (§4.1.3(5)). Individuals must be able to enter unassisted, operate, and exit the lift without assistance (4.11.3).
UFAS: Has same general requirement for elevators and exceptions similar to those in ADAAG. Platform lifts may be substituted for elevators in new construction or alterations "if no other alternative is feasible" (§4.1.2(5)). Lifts must facilitate unassisted entry and exit (but not "operation" of the lift as in ADAAG) (§4.11.3).
1) Historic buildings
ADAAG: Contains procedures for buildings eligible for listing in the National Register of Historic Places under the National Historic Preservation Act and for historic buildings designated under State or local law (§4.1.7).
UFAS: Contains requirements for buildings eligible for listing in the National Register of Historic Places under the National Historic Preservation Act that are also subject to the Architectural Barriers Act. UFAS does not contain provisions applicable to buildings and facilities that are designated as "historic" under State or local law. (Under title II, the UFAS provisions may be applied to any building that is eligible for listing on the National Register of Historic Places, regardless of whether it is also subject to the Architectural Barriers Act.) (§4.1.7).
2) Residential facilities/transient lodging
ADAAG:
* Hotels, motels, dormitories, and other similar establishments: Four percent of the first 100 rooms and approximately two percent of rooms in excess of 100 must be accessible to both persons with hearing impairments (i.e., contain visual alarms, visual notification devices, volume-control telephones, and an accessible electrical outlet for a text telephone) and to persons with mobility impairments. Moreover, a similar percentage of additional rooms must be accessible to persons with hearing impairments. In addition, where there are more than 50 rooms, approximately one percent of rooms must be accessible rooms with a special roll-in/transfer shower. There are special provisions for alterations (§§9.1‒9.4).
* Homeless shelters, halfway houses, and similar social service establishments: Homeless shelters and other social service entities must provide the same percentage of accessible sleeping accommodations as above. At least one type of amenity in each common area must be accessible. Alterations are subject to less stringent standards (§9.5).
UFAS: Contains requirements for residential occupancies with technical requirements for "dwelling units." No requirements for sleeping rooms for individuals with hearing impairments. No requirements for roll-in showers as in ADAAG. No standards for alterations (§§4.1.4(11); 4.34).
3) Restaurants
ADAAG: In restaurants, generally all dining areas and five percent of fixed tables (but not less than one) must be accessible. While raised or sunken dining areas must be accessible, inaccessible mezzanines are permitted under certain conditions. Contains requirements for counters and bars, access aisles, food service lines, tableware and condiment areas, raised speaker's platforms, and vending machine areas (but not controls). Contains some less stringent requirements for alterations (§5).
UFAS: Less detailed requirements. Does not address counters and bars. Raised platforms are allowed if same service and decor are provided. Vending machines and controls are covered. No special, less stringent requirements for alterations (§5).
4) Medical or health care facilities ADAAG: In medical care facilities, all public and common use areas must be accessible. In general purpose hospitals and in psychiatric and detoxification facilities, 10 percent of patient bedrooms and toilets must be accessible. The required percentage is 100 percent for special facilities treating conditions that affect mobility, and 50 percent for long-term care facilities and nursing homes. Uses terms clarified by the Department of Health and Human Services to describe types of facilities. Some descriptive information was added. Contains special, less stringent requirements for alterations (§6). UFAS: Uses different terms to describe types of facilities. Required clearances in rooms exceed ADAAG requirements. No special, less stringent requirements for alterations (§6).
5) Mercantile
ADAAG:
Counters:
* At least one of each type of sales or service counter where a cash register is located must be accessible. Accessible counters must be dispersed throughout the facility. Auxiliary counters are permissible in alterations (§7.2(1)). * At counters without cash registers, such as bank teller windows and ticketing counters, three alternatives are possible: (1) a portion of the counter may be lowered, (2) an auxiliary counter may be provided, or (3) equivalent facilitation may be provided by installing a folding shelf on the front of a counter to provide a work surface for a person using a wheelchair (§7.2(2)).
Check-out aisles:
* At least one of each design of check-out aisle must be accessible, and, in many cases, additional check-out aisles are required to be accessible (i.e., from 20 to 40 percent) depending on the number of check-out aisles and the size of the facility. There are less stringent standards for alterations (§7.3). UFAS:
Much less detail. At service counters, must provide an accessible portion of the counter or a nearby accessible counter. At least one check-out aisle must be accessible (§7).
6) Jails and prisons
ADAAG: No scoping requirements indicating how many cells need to be accessible.
UFAS: Five percent of residential units in jails, prisons, reformatories, and other detention or correctional facilities must be accessible (§4.1.4(9)(c)).
User Comments/Questions