Hello. Please sign in!

The Impact of Transfer Setup on the Performance of Independent Transfers: Phase I Final Report

Measures and Procedures
A custom-built modular, transfer station was designed and built and consisted of a height adjustable platform capable of a range between 10” to 29” with increments every inch (25.4-73.7 cm in 2.5 cm) with a fixed backrest 17” wide by 25” high (63.5x43.2 cm) and a 95° recline; a lateral grab bar (fixed height of 32” or 81.3 cm) and allows for attaching/detaching side guards (e.g. obstacle to transfer) and an optional front grab bar of varying height (Figure 1) of 19”-38” (48.3-96.5 cm) with increments every 2” (5.1 cm). The grab bars’ diameter is 1.5” (3.8cm). The space for the legs and feet has a fixed dimension of 14.5” deep by 22.5” wide (36.8x57.2cm).

Shows the initial setup of the custom-built modular transfer station.  The station consists of a height adjustable platform, a fixed backrest, and a lateral grab bar with a fixed height.  Also shown is the optional variable height grab bar in front of the platform.  There are two highlighted areas in the image, one area that indicates the (constrained) area for placement of the feet and the other shows an (unconstrained) area for positioning the mobility device next to the platform.

Figure 1 . Custom-built transfer station with the front grab bar, lateral grab bar, side guard, feet space, and space for WMD positioning highlighted.    

For the initial setup, the platform was adjusted to be level with the subject’s WMD seat, with no side guard or front grab bar in place. The subjects were asked to position themselves next to the platform as they normally would to prepare for a transfer. Angular orientation and linear distances of the WMD with respect to the front most corner of the platform were recorded (Figure 2).  Each subject was asked to perform a transfer from their WMD to the station and back to their WMD. Grab bar(s) use was noted.  Next, they were asked to perform five protocols in random order.  Subjects were asked to exercise sound judgment in performing the transfers and to only do transfers they felt comfortable and safe doing.  Subjects were spotted in the event they would begin to slip/fall during a transfer in which the case the transfer was declared ‘unattainable’. After each transfer in each protocol, changes made to device positioning (x, y, α, Figure 2) and leading/trailing hand placement were recorded.  The angle between the WMD and the transfer station is defined from 0°-180°. When the WMD is parallel to the transfer station and the subject is facing towards the front of the station the angle is defined as 0° and when the WMD is parallel to the transfer station but the subject is facing towards the back of the station the angle is defined as 180°.

This figure shows how the WMD was positioned with respect to the transfer station in order to calculate the overall space needed to transfer.  The WMD is angled next to the transfer station with the distance from the front tip of the WMD to the station marked as the width, and the distance from the front tip of the WMD to the back tip of the WMD marked as the depth.

Figure 2 . WMD position measures taken to calculate the overall space needed to transfer

Adjustable height protocol: From initial setup, only the height of the platform was adjusted incrementally: higher (Figure 3) and lower than the subject’s seat.  The amount of vertical distance that the seat was raised/lowered each time depended on the subject’s perceived and observed transfer abilities. The maximum and minimum heights the subject could transfer to/from the platform were recorded.  As WMD seat heights differed among subjects, we also computed the difference between their seat height and the absolute maximum and minimum height they attained to calculate height differentials.

This figure shows a manual wheelchair user transferring to the transfer station set at a higher (left) and lower (right) height than a wheelchair. The front bar is not attached to the transfer station.

Figure 3 . Subject transferring to the transfer station set at a higher (left) and lower (right) height than the wheelchair

Adjustable gap protocol: From initial setup, just the horizontal distance between the WMD and platform was incrementally increased by placing plywood blocks of 3.5” (8.9cm) width between the transfer station and the WMD (Figure 4).  The platform height remained level with their WMD seat height.  The amount of horizontal distance increased each time again depended on the subjects perceived and observed transfer abilities.  The maximum horizontal distance the subject could transfer to/from the platform was recorded.  

This figure shows an ambulatory manual wheelchair-using subject transferring to the station with a 7in gap between the WMD and the station.  The transfer station height is level with the height of the wheelchair seat to the ground.

Figure 4 . Person transferring with a 7in gap and the transfer station height at level with the wheelchair

Adjustable height/gap protocol: From the initial setup, a gap separating the device and platform was introduced with the plywood blocks of 3.5” (8.9cm) and then the height of platform was adjusted incrementally higher/lower (Figure 5). This procedure was repeated until the largest horizontal distance was reached. The maximum and minimum heights attainable with the largest horizontal distance were recorded. 

This figure shows a power wheelchair user transferring to the station with a 7in gap between the WMD and the station.  The user is transferring with a transfer board in place. The transfer station height is higher than the wheelchair seat height.

Figure 5 . Subject transferring with a 7in gap and the transfer station higher than the wheelchair.

Side guard protocol: From initial setup, two side guards adjusted 6” (15.2 cm) higher than the subject’s WMD seat were attached, and subjects were asked to perform a level height transfer.  Then the height of the platform was adjusted incrementally in height: higher and lower than the subject’s seat and the maximum transfer heights high/low that were attainable were recorded (Figure 6). Then from initial setup, the horizontal distance between the wheelchair and platform was incrementally increased and the maximum attainable gap distance was recorded. For all transfers with the side guard, side guard height was adjusted to be 6” higher than the WMD seat when the platform was level or lowered and 6” above the platform height when the platform was raised. 

This figure shows a manual wheelchair user transferring to the station with the side guard in place and the transfer station set higher than the wheelchair’s height.

Figure 6 . Subject transferring with the side guard in place and the transfer station higher than the wheelchair

Front grab bar protocol: From the initial setup, an adjustable height grab bar was placed in front of the platform which enabled an additional optional handheld to assist with transferring to/from the platform.  The horizontal distance between the center of the grab bar and the mid-center, front edge of the platform was 13.5”.  Two conditions in random order were tested: 1) front grab bar and no side guard and 2) both front grab bar and side guard present in the setup.  Subjects first performed a level height transfer in each condition and afterwards performed the variable height portion of the protocol as described previously (e.g. Adjustable height protocol).  For each condition (e.g. grab bar with side guard and grab bar without side guard), subjects were asked to select their preferred grab bar height for both 1) transferring to lower heights and 2) transferring to higher heights than their WMD seat height.  The preferred grab bar height was measured between the floor and the top of the grab bar surface.  Maximum and minimum heights attainable, front grab use, and grab bar heights for each the lower-height and higher-height transfers were recorded.

This figure shows a manual wheelchair user transferring to the station with the side guard and front grab bar in place and the transfer station set higher than the wheelchair height.

Figure 7. Subject transferring with the side guard and front grab bar in place and the transfer station higher than the wheelchair

[MORE INFO...]

*You must sign in to view [MORE INFO...]