This dryer protrudes more than 4" from the wall and is greater than 27" above the finish floor. Isn't this a violation of Section 307 Protruding Objects?
Section 307 Protruding Objects
General Comment or Question
Re: 308.2.1 Hand Dryer Reach Range Forward Unobstructed
Rosemarie Villegas | November 26, 2018 at 6:11PM (edited)
Related Keywords
Related Section Numbers
- 2010 ADA Standards for Accessible Design Pocket Guide (2)
- 1991 ADA Standards for Accessible Design (6)
- ADAAG Manual (2)
- ABA Accessibility Standard for GSA Facilities Pocket Guide (1)
Accurate: 100% (1 votes)
Helpful: N/A (0 votes)
Message 3 of 4
Re: Section 307 Protruding Objects
General Comment or Question
Re: 308.2.1 Hand Dryer Reach Range Forward Unobstructed
Jeff Foster | November 26, 2018 at 6:11PM (edited)
Yes, it is a protruding object hazard based solely on section 307, but so is the (code compliant) lavatory with its (required) 29" high front edge, and the 8" deep (code compliant) shelf mounted at the (required) height of 40" - 48" AFF.
Related Keywords
Related Section Numbers
- 2010 ADA Standards for Accessible Design Pocket Guide (2)
- 1991 ADA Standards for Accessible Design (6)
- ADAAG Manual (2)
- ABA Accessibility Standard for GSA Facilities Pocket Guide (1)
Accurate: N/A (0 votes)
Helpful: N/A (0 votes)
Message 2 of 4
Re: Section 307 Protruding Objects
General Comment or Question
Re: 308.2.1 Hand Dryer Reach Range Forward Unobstructed
Justin Kerfoot | November 26, 2018 at 6:11PM (edited)
Could you please direct me to the section in the code indicates that an 8" deep shelf at 40"-48" AFF is code compliant as stated? Thank you in advance!
Related Keywords
Related Section Numbers
- 2010 ADA Standards for Accessible Design Pocket Guide (2)
- 1991 ADA Standards for Accessible Design (6)
- ADAAG Manual (2)
- ABA Accessibility Standard for GSA Facilities Pocket Guide (1)
Accurate: N/A (0 votes)
Helpful: N/A (0 votes)
Message 4 of 4
Re: Section 307 Protruding Objects
General Comment or Question
Re: 308.2.1 Hand Dryer Reach Range Forward Unobstructed
Jeff Foster | November 26, 2018 at 6:11PM (edited)
Hi Justin,
Sorry I didn't see you question sooner.
See ADAS 603.4 and CBC 11B-603.4. The (maximum) depth of a shelf isn't noted, but you're unlikely to find many shelves less than 4" deep. The more blatant inconsistency is the lavatory, which is required to be 17" deep minimum due to the required forward approach clear floor/knee and toe space, and must provide knee clearance that is a minimum of 27" high (606.2; 305; 306).
Related Keywords
Related Section Numbers
- 2010 ADA Standards for Accessible Design Pocket Guide (2)
- 1991 ADA Standards for Accessible Design (6)
- ADAAG Manual (2)
- ABA Accessibility Standard for GSA Facilities Pocket Guide (1)
Accurate: N/A (0 votes)
Helpful: N/A (0 votes)
Message 1 of 4