2010 ADA Standards for Accessible Design Pocket Guide
806 Transient Lodging Guest Rooms
806.1 General.
Transient lodging guest rooms shall comply with 806. Guest rooms required to provide mobility features shall comply with 806.2. Guest rooms required to provide communication features shall comply with 806.3.
806.2 Guest Rooms with Mobility Features.
Guest rooms required to provide mobility features shall comply with 806.2.
806.2.1 Living and Dining Areas.
Living and dining areas shall be accessible.
806.2.2 Exterior Spaces.
Exterior spaces, including patios, terraces and balconies, that serve the guest room shall be accessible. [S.H. 9.2.2(6)(d)]
806.2.3 Sleeping Areas.
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed. The clear floor space shall be positioned for parallel approach to the side of the bed.
EXCEPTION: Where a single clear floor space complying with 305 positioned for parallel approach is provided between two beds, a clear floor or ground space shall not be required on both sides of a bed.
806.2.4 Toilet and Bathing Facilities.
At least one bathroom that is provided as part of a guest room shall comply with 603. No fewer than one water closet, one lavatory, and one bathtub or shower shall comply with applicable requirements of 603 through 610. In addition, required roll-in shower compartments shall comply with 608.2.2 or 608.2.3. Toilet and bathing fixtures required to comply with 603 through 610 shall be permitted to be located in more than one toilet or bathing area, provided that travel between fixtures does not require travel between other parts of the guest room.
806.2.4.1 Vanity Counter Top Space.
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be provided in accessible guest toilet or bathing rooms.
806.2.5 Kitchens and Kitchenettes.
Kitchens and kitchenettes shall comply with 804.
806.2.6 Turning Space.
Turning space complying with 304 shall be provided within the guest room.
806.3 Guest Rooms with Communication Features.
Guest rooms required to provide communication features shall comply with 806.3.
806.3.1 Alarms.
Where emergency warning systems are provided, alarms complying with 702 shall be provided.
806.3.2 Notification Devices.
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell. Notification devices shall not be connected to visible alarm signal appliances. Telephones shall have volume controls compatible with the telephone system and shall comply with 704.3. Telephones shall be served by an electrical outlet complying with 309 located within 48 inches (1220 mm) of the telephone to facilitate the use of a TTY.
User Comments/Questions
Add Comment/Question