2013 California Standards for Accessible Design Pocket Guide

SECTION 1008 DOORS, GATES AND TURNSTILES

[DSA-AC]  In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for applications listed in Section 1.9.1 regulated by the Division of the State Architect—Access Compliance, shall also comply with Chapter 11A or Chapter 11B, Sections 11B-206.5 and 11B-404, as applicable.

1008.1.9 Door operations.  ...

1008.1.9.7  Delayed egress locks.  ...

5.     A sign shall be provided on the door located above and within 12 inches (305 mm) of the release device reading:  “KEEP PUSHING. THIS DOOR WILL OPEN IN 15 [30] SECONDS ALARM WILL SOUND” Sign lettering shall be at least 1 inch (25 mm) in height and shall have a stroke of not less than 1/8 inch (3.2 mm).

5.1   A tactile sign shall also be provided in Braille and raised characters, which complies with Chapter 11B, Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5.