11B-206.5 Doors, doorways, and gates.
Doors, doorways, and gates providing user passage shall be provided in accordance with Section 11B-206.5.
11B-206.5.1 Entrances.
Each entrance to a building or facility required to comply with Section 11B-206.4 shall comply with Section 11B-404.
[2010 ADAS] 206.5.1 Entrances. Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404.
11B-206.5.2 Rooms and spaces.
Within a building or facility, every door, doorway or gate serving rooms and spaces complying with this chapter shall comply with Section 11B-404.
[2010 ADAS] 206.5.2 Rooms and Spaces. Within a building or facility, at least one door, doorway, or gate serving each room or space complying with these requirements shall comply with 404.
ETA Editor's Note
The ADA requirements included at Subsections 11B-206.5.1 and 11B-206.5.2 are provided for information only. The CBC scoping requirements are more inclusive.
11B-206.5.3 Transient lodging facilities.
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall comply with Section 11B-404.2.3 _|Doors, Doorways, and Gates; Clear Width|_.
Exception: Shower and sauna doors in guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall not be required to comply with Section 11B-404.2.3.
11B-206.5.4 Residential dwelling units.
In residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, all doors and doorways providing user passage shall comply with Section 11B-404.