2013 California Standards for Accessible Design Pocket Guide
11B-404.2.4 Maneuvering clearances.
Minimum maneuvering clearances at doors and gates shall comply with Section 11B-404.2.4. Maneuvering clearances shall extend the full width of the doorway and the required latch side or hinge side clearance.
[S.H. 1133B.2.4.2] [Safe Harbor only applies to existing primary entrances.]
Exception: Reserved.
[2010 ADAS] EXCEPTION: Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door.
ETA Editor's Note
2013 CBC does not include the 2010 ADAS Exception at 404.2.4. Therefore, 2013 CBC requirements related to entry doors at patient rooms are more stringent.
11B-404.2.4.1 Swinging doors and gates.
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1.
TABLE 11B-404.2.4.1
MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
TYPE OF USE |
MINIMUM MANEUVERING CLEARANCE |
||
---|---|---|---|
Approach direction |
Door or gate side |
Perpendicular to doorway |
Parallel to doorway (beyond latch side unless noted) |
From front |
Pull |
60 inches (1524 mm) |
18 inches (457 mm)5 |
From front |
Push |
48 inches (1219 mm) |
0 inches (0 mm)1 |
From hinge side |
Pull |
60 inches (1524 mm) |
36 inches (914 mm) |
From hinge side |
Push |
44 inches (1118 mm)2 [2010 ADAS] 42 inches, add 6 inches if closer and latch provided |
22 inches (559 mm)3 |
From latch side |
Pull |
60 inches (1524 mm) [2010 ADAS] 48 inches, add 6" if closer provided |
24 inches (610 mm) |
From latch side |
Push |
44 inches (1118 mm)4 [2010 ADAS] 42 inches, add 6" if closer provided |
24 inches (610 mm) |
1. Add 12 inches (305 mm) if closer and latch are provided. 2. Add 4 inches (102 mm) if closer and latch are provided. 3. Beyond hinge side. 4. Add 4 inches (102 mm) if closer is provided. 5. Add 6 inches (152 mm) at exterior side of exterior doors. |
MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors .
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2.
TABLE 11B-404.2.4.2
MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS OR GATES, MANUAL SLIDING DOORS, AND MANUAL FOLDING DOORS
MINIMUM MANEUVERING CLEARANCE |
||
---|---|---|
Approach direction |
Perpendicular to doorway |
Parallel to doorway (beyond stop/latch side unless noted) |
From Front |
48 inches (1219 mm) |
0 inches (0 mm) |
From side1 |
42 inches (1067 mm) |
0 inches (0 mm) |
From pocket/hinge side |
42 inches (1067 mm) |
22 inches (559 mm)2 |
From stop/latch side |
42 inches (1067 mm) |
24 inches (610 mm) |
1. Doorway with no door only. |
FIGURE 11B-404.2.4.2
MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND FOLDING DOORS
FIGURE 11B-404.2.4.2
MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND FOLDING DOORS
11B-404.2.4.3 Recessed doors and gates .
Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches (457 mm) of the latch side at an interior doorway, or within 24 inches (610 mm) of the latch side of an exterior doorway, projects more than 8 inches (203 mm) beyond the face of the door, measured perpendicular to the face of the door or gate.
[2010 ADAS] 404.2.4.3 Recessed Doors and Gates. Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches (455 mm) of the latch side of a doorway projects more than 8 inches (205 mm) beyond the face of the door, measured perpendicular to the face of the door or gate.
ETA Editor's Note
2013 CBC latch side clearance at exterior doors is more stringent than 2010 ADAS.
FIGURE 11B-404.2.4.3 ‡‡
MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES
11B-404.2.4.4 Floor or ground surface.
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302. Changes in level are not permitted.
Exceptions:
1. Slopes not steeper than 1:48 shall be permitted.
2. Changes in level at thresholds complying with Section 11B-404.2.5 shall be permitted.
User Comments/Questions
Add Comment/Question