2019 California Standards for Accessible Design Guide (effective January 1, 2020 with July 1, 2021 amendments)
11B-1008.3.2 Transfer steps.
Transfer steps shall be provided where movement is intended from transfer platforms to levels with elevated play components required to be on accessible routes. Transfer steps shall comply with Section 11B-1008.3.2.
11B-1008.3.2.1 Size.
Transfer steps shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.
11B-1008.3.2.2 Height.
Each transfer step shall be 8 inches (203 mm) high maximum.
11B-1008.3.2.3 Transfer supports.
At least one means of support for transferring shall be provided.
Advisory 11B-1008.3.2.3 Transfer supports. Transfer supports are required on transfer platforms and transfer steps to assist children when transferring. Some examples of supports include a rope loop, a loop type handle, a slot in the edge of a flat horizontal or vertical member, poles or bars, or D rings on the corner posts. ◼
11B-1008.3.2.4 Contrasting stripe.
Striping complying with Section 11B-504.4.1 shall be provided at each transfer step.