11B-213.3.2 Water closets.
Where water closets are provided, at least 5 percent but no fewer tan one shall comply with Section 11B-604.
[2010 ADA Standards] 213.3.2 Water Closets. Where water closets are provided, at least one shall comply with 604.
ETA Editor's Note
With the revisions to scoping requirements in Subsections 11B-213.3.1 through 11B-213.3.4 implemented by the 2013 CBC Supplement dated July 1, 2015, DSA-AC increased the number of accessible water closets required at very large multi-user toilet rooms. Since the CBC path of travel obligation to remove existing barriers only allows "safe harbor" dating back to the "immediately preceding edition" (see 11B-202.4, Exception 2), existing facilities having toilet rooms that do not comply with the increased scoping will be compelled by this obligation to upgrade these toilet rooms if alterations are performed to an area served by them.