2022 California Standards for Accessible Design Guide (effective January 1, 2023)
11B-232.5 Visiting areas.
Visiting areas shall comply with Section 11B-232.5.
11B-232.5.1 Cubicles and counters.
At least 5 percent, but no fewer than one, of cubicles shall comply with Section 11B-902 on both the visitor and detainee sides. Where counters are provided, at least one shall comply with Section 11B-904.4.2 on both the visitor and detainee or inmate sides.
Exception: The inmate or detainee side of cubicles or counters at non-contact visiting areas not serving holding cells or housing cells required to comply with Section 11B-232 shall not be required to comply with Section 11B-902 or 11B-904.4.2.
11B-232.5.2 Partitions.
Where solid partitions or security glazing separate visitors from detainees or inmates at least one of each type of cubicle or counter partition shall comply with Section 11B-904.6.
ETA Editor's Note
The ADA requirements included at Section 11B-232 are provided for information only. The CBC scoping requirements are more inclusive.
User Comments/Questions
Add Comment/Question