11B-411.2.1.2.3 Accessibility function button.

The accessibility function button shall be identified by the International Symbol of Accessibility and a raised indication. The International Symbol of Accessibility shall comply with Section 11B-703.7.2.1, and shall be 5/8 inch (15.9 mm) minimum in height. The indication shall be three raised dots. Each dot shall have a base diameter of 0.059 inch (1.5 mm) minimum and 0.063 inch (1.6 mm) maximum and a height of 0.025 inch (0.6 mm) minimum and 0.037 inch (0.9 mm) maximum. The dots shall be spaced ΒΌ inch (6.4 mm), measured center to center, in the form of an equilateral triangle with a vertex pointing up. The accessibility function button shall not be provided with a key repeat function.

International Symbol of Accessibility shown to measure 5/8" high, accompanied with three dots in an equilateral triangular shape with each dot 1/4" apart, serving as raised indication of the International Symbol of Accessibility

Visual and Raised Information

International Symbol of Accessibility shown to measure 5/8" high, accompanied with three dots in an equilateral triangular shape with each dot 1/4" apart, serving as raised indication of the International Symbol of Accessibility

Visual and Raised Information

FIGURE 11B-411.2.1.2.3 DESTINATION-ORIENTED ELEVATOR ACCESSIBILITY FUNCTION BUTTON INDICATION