Hello. Please sign in!

Note: This document or portion of document references a state or local code that is stricter than the 2010 ADA Standards requires.

11B-604.9 Water closets and toilet compartments for children's use.

Water closets and toilet compartments for children's use shall comply with Section 11B-604.9. When the exception in Section 11B-604.1 is used, the suggested dimensions of Table 11B-604.9 for a single age group shall be applied consistently to the installation of a water closet and all associated components.

DOJ icon
Advisory 11B-604.9 Water closets and toilet compartments for children's use. The requirements in Section 11B-604.9 are to be followed where the exception for children's water closets in Section 11B-604.1 is used. Table 11B-604.9 provides additional guidance in applying the specifications for water closets for children according to the age group served and reflects the differences in the size, stature, and reach ranges of children ages 3 through 12. The specifications chosen should correspond to the age of the primary user group. The specifications of one age group should be applied consistently in the installation of a water closet and related elements. 

 TABLE 11B-604.9 SUGGESTED DIMENSIONS FOR CHILDREN’S USE

Suggested Dimensions For Water Closets Serving Children Ages 3 Through 12

  Ages 3 and 4 Ages 5 through 8

Ages 9 through 12

Water Closet Centerline

12 inches (305 mm)

12 to 15 inches (305 to 381 mm)

15 to 18 inches (381 to 457 mm)

Toilet Seat Height

11 to 12 inches (279 to 305 mm) 12 to 15 inches (305 to 381 mm)

15 to 17 inches (381 to 432 mm)

Grab Bar Height

18 to 20 inches (457 to 508 mm) 20 to 25 inches (508 to 635 mm)

25 to 27 inches (635 to 686 mm)

Dispenser Height

14 inches (356 mm) 14 to 17 inches (356 to 432 mm)

17 to 19 inches (432 to 483 mm)

11B-604.9.1 Location.

The water closet shall be located with a wall or partition to the rear and to one side. The centerline of the water closet shall be 12 inches (305 mm) minimum and 18 inches (457 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment specified in Section 11B-604.8.2. Compartments shall be arranged for left-hand or right-hand approach to the water closet.

11B-604.9.2 Clearance.

Clearance around a water closet shall comply with Section 11B-604.3.

11B-604.9.3 Height.

The height of water closets shall be 11 inches (279 mm) minimum and 17 inches (432 mm) maximum measured to the top of the seat. Seats shall not be sprung to return to a lifted position.

11B-604.9.5 Flush controls.

Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor. Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2.

11B-604.9.6 Dispensers.

Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the centerline of the dispenser. The outlet of the dispenser shall be 14 inches (356 mm) minimum and 19 inches (483 mm) maximum above the finish floor. There shall be a clearance of 1½ inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow.